Gold Member Since 2017
Audited Supplier
Shijiazhuang JHR Import & Export Co., Ltd.

Cooling Tower Manufacturer, FRP Cooling Tower, Fiberglass Cooling Tower manufacturer / supplier in China, offering Industrial Fans 1500m3/H Cooling Tower Manufacturer, CNC Controlled Pipe Filament Winding Machine FRP Pipe Making Machine, GRP Pipe Winding Machinery FRP Pipe Filament Winding Machine and so on.

(/ )

Supplier Homepage Product FRP COOLING TOWER Industrial Fans 1500m3/H Cooling Tower Manufacturer

Industrial Fans 1500m3/H Cooling Tower Manufacturer

FOB Price: US $1,500-5,000 / Piece
Min. Order: 5 Pieces
Min. Order FOB Price
5 Pieces US $1,500-5,000/ Piece
Get Latest Price
Port: Tianjin, China
Production Capacity: 1000 Per Month
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: cooling tower manufacturer
  • Ventilation Mode: Mechanical Ventilation
  • Air Contact Form: Wet
  • Tower Shape: Round
  • Application Fields: Air Conditioning
  • Condition: New
  • Type: Standard, Low Noise, High Temperature, Industrial
  • Shape: Round, Square
  • FRP Colour: Any Color Is Ok
  • Quality Guarantee Period: 12 Months
  • Package: According as Customer′s Requirement
  • Transport Package: According to Customers Requirements
  • Origin: China
  • Cooling Method: Counter Flow
  • Material: FRP
  • Air Contact Way: Open
  • Noise Level: Ultra Quiet
  • Certification: ISO
  • Main Material: FRP GRP Fiber Reinforce Plastic
  • Net/Operation Weight: 500kg-100000kg
  • After-Sales Service Provided: Overseas Service Center Available
  • Delivery Time: Within 15days After Received Advanced Payment
  • Usage Life: 30 Years`
  • Trademark: JHR
  • Specification: can be customized
  • HS Code: 84195000
Product Description
industrial fans 1500m3/h cooling tower manufacturer

Product features:
1 Excellent performance
2 High Quality
3 Environmental protection and energy conservation
4 Good shape with small outside size, light weight
5 Low Noise: The lowest noise blower and unique noise elimination technology is adopted to reduce the noise to a minimum level.
6 Type: Standard, low noise and High temperature, industrial type to meet customer's needs.

Structures and working principle:
Optimum structure: All structures can be treated with rust-removing, hot dipped galvanized Steel. All can bear corrosion, have high strength, be easily assembled and have elegant surface.
    1 Body: The cooling tower body is made of stabilization material---FRP, which is anti-aging, anti-corrosion, resisting ultraviolet radiation, without fading and distortion. It has long service life.
    2 Fan: Use special fan with variable section, twist and pitching blade. The fan Works at an equal speed, a low self moving pressure, an energy-saving use and a low noise. Fixing angle of blade is changeable to meet the work demands and improve the efficiency. The angles of all fans are regulative and axial-flow, which made of advanced engineering plastics.
    3 Motor: All the motors (380V/3φ /50Hz mostly) of the cooling tower are sealed, which can be used in the severe weather and circumstances.
    4 Fill: The fill is made of polyvinyl chloride which is hard and heat-resisting, be able to be extended the time and space of heat exchange. The temperature in the water is up to 54. And the special structure enables the water to touch the fill in the biggest area with low air resistance. The energy exchanging efficiency is very high.
    5 Rotating pipe model which is made of FRP.
6 Brackets: All steel structure brackets are galvanized and corrosion resistant. The usage life is twice longer compared with similar products.
    7 The casing and water plate of the cooling tower are made of fiberglass, which will not be corroded, and no painting is needed. They can be used for a long time with very low maintenance cost.


Reference specification  round counter flow cooling tower CDBNL3 series
TypeT=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h)Dimension (mm)
air volume (m3/h)
Fan diameter
(mm)

Motor
power
(kw)
Weight
(kg)
Water pressure
104pa
Noise
Db(A)
Diameter
Dm
t=5ºCt=8ºCt=5ºCt=8ºCtotal heightmaximum diameterSelf
-
weight
Running
weight
Dm10m16m
CDBNL3-12
CDBNL3-20
CDBNL3-30
CDBNL3-40
12
20
30
40
9
15
22
30
15
24
35
46
10
17
27
34
2972
3062
3281
3781
1600
2000
2400
2400
7200
12400
18000
21500
700
800
1200
1200
0.6
0.8
0.8
1.1
306
330
546
618
584
644
1100
1258
1..90
2.00
2.21
2.60
50.0
50.0
51.0
51.0
37.1
36.3
39.5
39.5
33.5
32.6
35.9
35.9
1.5
1.5
1.8
1.8
CDBNL3-50 CDBNL3-60 CDBNL3-70 CDBNL3-8050
60
70
80
37
44
51
61
57
68
79
92
44
51
60
70
3816
4066
4153
4403
2800
2800
3300
3300
28000
32300
39200
43400
1400
1400
1600
1600
1.5
1.5
2.2
2.2
756
950
998
1083
1640
1752
2272
2451
2.65
2.90
2.78
2.03
51.0
52.0
52.0
52.5
40.7
41.7
43.0
43.5
37.1
38.1
39.0
39.5
2.1
2.1
2.5
2.5
CDBNL3-100
CDBNL3-125
CDBNL3-150
CDBNL3-175
100
125
150
175
74
92
112
131
114
142
171
200
86
108
129
150
4410
4690
4765
5015
3900
3900
4600
4600
56000
67200
84000
94300
1800
1800
2400
2400
3.0
4.0
4.0
5.5
1230
1320
2045
2182
3322
3422
4475
4808
2.86
3.15
2.90
3.15
53.0
54.0
54.0
55.0
46.0
46.7
47.5
48.5
42.0
43.4
44.1
45.1
3.0
3.0
3.6
3.6
CDBNL3-200
CDBNL3-250
CDBNL3-300
CDBNL3-350
200
250
300
350
153
186
225
267
231
283
334
395
180
215
260
304
5194
5444
5713
5963
5700
5700
6400
6400
112000
134300
168000
187400
2800
2800
3400
3400
5.5
7.5
7.5
11.0
2663
2875
4132
4434
6123
6892
9805
10479
3.01
3.26
3.50
3.75
55.0
56.0
56.0
56.5
49.6
50.6
51.8
52.3
46.3
47.3
48.5
49.0
4.2
4.2
5.0
5.0
CDBNL3-400
CDBNL3-450
CDBNL3-500
CDBNL3-600
400
450
500
600
301
343
375
454
455
514
576
680
341
387
427
516
6269
6519
6890
7390
7400
7400
8200
8200
224000
242000
280000
302200
3800
3800
4200
4200
11.0
11.0
15.0
18.5
4995
5341
6612
7414
12782
14160
17102
12904
3.60
3.85
3.70
4.20
57.0
57.0
57.0
58.0
53.8
53.8
55.0
56.0
50.7
50.7
51.9
52.4
5.9
5.9
6.6
6.6

Reference specification Square cross-flow cooling tower AHBLD, HBLCD series
TypeT=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h)Dimension(mm)air volume (m3/h)Fan diameter
(mm)
Motor installed capacity
(Kw)
Weight
(t)
Noise
db(A)
t=5ºCt=8ºCt=5ºCt=8ºClengthwidthHeightself-weightRunning
weight
AHBLD
HBLD-300
30022534325572503810451416700034007.55.8513.3859.0
AHBLD
HBLD-500
500377576427803046505320260000420011.09.2017.2461.5
AHBLD
HBLD-700
700528803596893066405320370000500018.512.9526.0562.6
AHBLCD
HBLCD-300
300225343255106503810623016700034007.57.0514.1852.5
AHBLCD
HBLCD-500
500377576427116404650703026000420011.010.818.8453.7
AHBLCD
HBLCD-700
700528803596125406640718037000500018.514.7526.8154.5

Reference specification Square counter flow cooling tower
DFN series
TypeT=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h)Dimension (mm)air volume (m3/h)Fan   diameter
(mm)
Motor
power
(kw)
Weight
(t)
intake pressure 104paNoise
Db(A)
diameter Dm
t=5ºCt=8ºCt=5ºCt=8ºCtotal heightwidthBself-weightRunning
weight
Dm10m16m
DFNL-100
DFNDP-100
DFNGP-100
10074.4118.7863830
4390
4690
26006200018003.0/1.51.9
2.16
2.46
2.44
3.78
5.7
6.25952473.02
DFNL-150
DFNDP-150
DFNGP-150
150109.8175.1126.94050
4670
4970
30008400024004.0/2.02.6
2.91
3.31
3.32
5.07
7.63
6.360.55450.63.47
DFNL-200
DFNDP-200
DFNGP-200
200148.9237.4172.14340
4960
5260
360011500028005.5/2.73.1
3.55
4.44
4.13
6.66
10.56
6.56255.652.34.15
DFNL-300
DFNDP-300
DFNGP-300
300224.9350.5258.35010
5690
5990
430015860034007.5/3.74.4
5.04
5.91
5.88
9.48
14.79
5.86257.854.54.94
DFNL-400
DFNDP-400
DFNGP-400
400299.9476.4344.45300
6040
6340
4800213000380011/5.55.3
6.1
6.96
7.14
10.57
18.02
662.558.855.75.51
DFNL-500
DFNDP-500
DFNGP-500
500374.9584.3430.45900
6700
7000
5300265000380015/7.56.6
7.58
8.64
8.85
13.11
19.7
6.462.559.356.26.08
DFNL-600
DFNDP-600
DFNGP-600
600448.5698.9514.96140
6980
7280
6000317500420015/7.58.42
9.68
10.85
11.3
34.56
28.13
6.562.560.557.46.88
DFNL-750
DFNDP-750
DFNGP-750
750561.7875.3644.96440
7290
7590
6800400000420022/1110.8
12.41
13.84
14.5
23.51
36.04
6.86361.458.47.79
DFNL-900
DFNDP-900
DFNGP-900
900673.41049.5773.26950
7900
8200
7300490000470030/1512.5
14.36
15.93
16.76
25.46
38.13
763.862.9608.36
DFNL-1050
DFNDP-1050
DFNGP-1050
1050786.61225.9903.17150
8100
8400
7800556000470030/1515.1
17.22
18.94
19.97
31.82
48.14
764.663


Trial order is acceptable. Sample is available.
Welcome to inquire, we will feedback within  24 hours.
Send your message to this supplier
Avatar
Mrs. Alice Li
*From:
To: Mrs. Alice Li
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now